Radio settings

Here you set how Web Radio Control operates each radio: how long it may transmit, who may switch it on and off, the lines switched around its keying, the timing of the Morse keyer, the bands it offers and how often it is read. These are the settings of Web Radio Control. What to set in the menu of the radio itself, so that it works from afar, is on Supported radios.

You set them in Settings › Station › Radios:

  • Defaults for radios, first in the list, holds the rules every radio follows until it has its own. Its Operating tab also holds the telemetry and the band plan of the station.
  • Each radio, on its Operating tab: Operating rules for this radio alone, and Reading the radio, how often it is read.
  • Advanced control settings, a tab of each radio, holds how the station runs its control through Hamlib.

Power users and the administrator change the operating rules and the reading. Only the administrator sees the advanced control settings. A rule changed on one radio shows This radio in blue beside it, and Reset to … there makes it follow the defaults again (see Defaults for each kind of device). A switch or a choice takes effect at once. A number waits in the bar at the bottom of the page until you choose Save.

Transmitting

SettingWhat it doesUnless you change it
Transmit time limitTransmitting stops after this long, from 5 seconds to an hour. The last safety for a transmission that nobody ends.3 minutes
Transmitting disabledNo one can transmit with the radio while this is on: its PTT, CW text and keys are refused.Off
Restrict switching on and offOnly power users and administrators can switch the radio on and off. Other users operate it, but can’t switch it on or off.Off
Switched on as a user connectsA radio found switched off is switched on, once, as a user who may operate it connects to the station.Off
Full output powerThe output of the radio at full RF power, in watts. The meters, the power of a logged contact and the transmit limits take the RF power as a share of it. 0 uses the power that Hamlib gives.0

Set Full output power where Hamlib gives the power of the radio wrongly, or not at all. A radio of 100 W at 50% RF power then counts as 50 W on every band (see Transmit limits).

Keep the transmit time-out timer of the radio on too, if it has one. It stops a transmission when the station control computer or its USB link fails. Each tested radio has its timer in Supported radios.

Switched on as a user connects

With Switched on as a user connects on, a radio that the station knows to be switched off is switched on when a user who may operate it connects: as Web Radio Control opens or connects again, as WRC Link starts, or as an application logs in to the station. It happens once for each connection.

  • A radio that is still starting, or not answering, is left as it is.
  • The radio is switched on only for a user who could choose Power on themselves: they may operate it, hold its reservation where it needs one, and are a power user or an administrator if Restrict switching on and off is on. Otherwise the radio stays off, and nothing is said.
  • If the radio doesn’t switch on, the user is told why in a notification.

Who holds the transmitter

The PTT of a radio belongs to the browser tab or the link of WRC Link that keyed it.

  • The tab releases it when it is closed or reloaded, and when its user logs out.
  • The station releases it when the connection of the tab closes or goes silent. A crashed browser or a lost network is noticed within about 15 seconds. The radio events list each such release.
  • No one else keys over it. While another user transmits, the PTT button of the others says so, and only a power user or an administrator can press it, to release that PTT.
  • An application keying the radio through WRC Link, such as WSJT-X, passes the same checks as the PTT button.

The sequencer

The Sequencer is for a radio with lines that are switched while it transmits, such as the keying line of an amplifier or a preamplifier relay. You choose those lines on the Keying step of the radio, under Switched while transmitting (see Add a device).

  • Lines on before the radio keys: how long the lines are on before the radio is keyed.
  • Lines off after the radio unkeys: how long the lines stay on after the radio is released.

Both are 0 ms unless you change them. Every transmission that the station keys goes in this order: the PTT button, an application through WRC Link, a test, a CW text or a key.

  1. The lines switched while transmitting go on.
  2. Lines on before the radio keys passes.
  3. The PTT of the radio is keyed, and the radio confirms it.
  4. For CW, the lead of the Morse keyer passes, and the first element goes.

At the end, the PTT is released, Lines off after the radio unkeys passes, and the lines go off. If the radio stops transmitting by itself, such as by its own time-out timer, the station releases its PTT at the next read and switches the lines off after the same wait.

The Morse keyer

The software keyer of the station keys the transmitter itself. These settings set how it starts and ends a keying. A change applies once the keyer isn’t keying.

SettingWhat it doesUnless you change it
Lead before a textThe time from keying the PTT to the first element of a text, a macro or WinKeyer emulation.50 ms
Lead before keying by handThe time from keying the PTT to the first key-down of a straight key or paddles, in Web Radio Control or in WRC Link.50 ms
Tail after a textHow long the transmitter stays keyed after the last element of a text. A text sent in that time goes out on the same keying.100 ms

There is no lead while the transmitter is keyed already, or with PTT control off, when the break-in of the radio keys it. Tick, Buffer, Delay and Transmitter released after, shown among the advanced settings, set how keying from a browser is played: a key is played a little late, to even out the delays of the network. Keep them as they are unless WRC support asks.

With SW off in the CW keyer, the radio keys a text with its own keyer. The leads, the tail and the sequencer then don’t apply, and an amplifier is keyed by the SEND output of the radio (see Send CW).

Meter scales

The radio doesn’t report the range of its supply meters, so set them here:

SettingUnless you change it
VOLT scale up to, VOLT red below, VOLT red above16 V, 12 V, 15 V
CURR scale up to, CURR red above25 A, 22 A

The defaults suit a 13.8 V transceiver (see Meters).

Telemetry and the band plan

These two are among the defaults alone, for every radio:

  • Time per telemetry point: the time each point of the telemetry charts covers, 500 ms unless you change it. Telemetry kept: how long the charts keep those points, 60 minutes unless you change it. Longer windows show one point a minute, for up to a day. A change clears the telemetry of the radios, and the charts start again (see Telemetry).
  • Band plan: the band plan of the station, for every user who hasn’t chosen their own in My settings › Bands. IARU Region 1 unless you choose another (see Band plans).

The bands of a radio

The band menu and band up and down offer the bands the radio receives on, by the frequency ranges Hamlib gives for its model. Those are the nominal ranges of the model, not of your unit: a European IC-7610 may be listed with a band it can’t transmit on. Under Bands, set each band of the band plans of the station where the radio differs:

  • By the frequency ranges: as the ranges of the radio give it. This is the default.
  • Transmit: offered, to transmit on, even where the ranges leave it out.
  • Receive only: offered, marked RX only in the band menu.
  • Not offered: left out of the band menu and band up and down.

A choice here wins over the ranges, for every user and every band plan, at once. It doesn’t stop the radio transmitting: the radio itself refuses where it can’t (see The band menu).

How often the radio is read

Reading the radio, on the Operating tab, chooses a Profile:

ProfileWhen to use it
LightAbout half as often as Normal. For a slow connection to the radio, such as CI-V at 19200 baud or a serial port reached over the network, for a busy Raspberry Pi, or for a station left running unattended.
NormalThe usual periods. What you see follows the radio closely. This is the default.
DetailedAbout twice as often as Normal. For a fast connection, such as an Icom on USB at 115200 baud, when tuning and the meters should follow at once.
CustomAt the periods you set.

Choose a lighter profile on the one radio that needs it. The others keep theirs.

With Custom, Periods sets State read every, Meters read every and how many reads go between two full ones, which also read what changes rarely. Under them, each field of the state and each meter has its schedule, while receiving and while transmitting: Every read, Full reads, Slow reads or Never. Choose Never for a field that the radio answers wrongly, or that Hamlib can’t read for it. A field that fails five reads in a row is marked Keeps failing. Set to Never?

Off or not answering sets how a radio that is off or doesn’t answer is checked: Checked every, Failed reads before off and Answers before on. The profiles don’t change them.

Advanced control settings

The Advanced control settings tab holds how the station runs the radio through Hamlib, the program that talks to it. The defaults suit most radios: an empty field uses the value shown in it. A change here is saved first, and applied with Apply and restart, as a change of the connection is (see Save and apply a change).

  • Audio stream: the Output sample rate and Capture sample rate, 48000 Hz unless set, the Input channels and Output channels, the Output queue and the Output monitor interval. Set the capture rate to 96000 Hz only for an audio interface that can capture at it.
  • Connection to device control: Wait to connect, Wait for an answer, Wait to send and Retries, how the station talks to the Hamlib program of the radio, not to the radio itself.
  • Device control: the Hamlib program the station runs for the radio. Log detail is how much it reports, Errors unless you choose Warnings, Verbose or Everything (trace). Start within, Start again after and Exit within time its start and end. Extra options are passed to it as they are.
  • Radio parameters: the own settings of Hamlib for the model, such as its timing, the serial line, PTT and the CI-V address of an Icom. Each shows where its value comes from: Own value, Web Radio Control default or Model default. View as text shows them as name=value lines, and Other Hamlib parameters lists the rest, with a search. A value that the model no longer takes is listed under Left out when the Hamlib daemon starts.

The DTR and RTS lines of the serial port of a radio are off unless you set them, so that a radio keying CW or PTT from one of them isn’t keyed while the station runs. RTS and DTR on the Connection tab set them: On for an interface powered from that line, or for a radio that sends nothing while RTS is off, No change to leave the line as the port opened it. The Kenwood TS-480 and TS-870S send nothing while RTS is off, so their RTS is on unless you set it off, shown as On (suggested) (see Kenwood radios). A line that keys the PTT of the radio shows Keys the radio, as Hamlib sets it.

To find why a radio misbehaves, set Log detail to Verbose or Everything (trace), save and apply, then read the events of the radio (see Restart, logs and diagnostics). Put it back to Errors afterwards.

Last updated on